RoHS Compliant Made in USA

Scope:

Cathodic protection cable helps prevent rust on mechanical equipment and exposed metal structures, including storage tanks, pipelines, wells, offshore oil platforms, subsea equipment, and ocean vessels.

Applicable Standards and Tests:

  • ASTM B-1, B-3, B-8, AND B-33
  • UL 1581
  • ICEA S-95-658/NEMA WC70

Features:

  • 600V RATED
  • DIRECT BURIAL RATED
  • 75°C MAX CONTINUING OPERATING TEMPERATURE IN WET OR DRY LOCATIONS

Construction:

Conductors:

Single conductors are solid or stranded and annealed or hardened uncoated copper.

Insulation:

Conductors are insulated with a concentrically applied HMWPE (high molecular weight polyethylene).

LLDPE (linear low density polyethylene) is standard and HDPE (high density polyethylene) is available on request.

Identification and Packaging:

Print legends on the wire include the manufacturer, conductor size, voltage rating, UL symbol (if applicable) and type designation. Standard length spools are 500 or 2500 feet.

Print Wheel:

KRIS-TECH WIRE CO. #XX AWG HMWPE CATHODIC PROTECTION CABLE

Value Add Service:

  • CUSTOM LENGTHS AND PUT-UPS
  • 12 AVAILABLE COLORS
  • WIRE PARALLELING AND CABLING
  • WIRE STRIPING
  • CUSTOM PRINT LEGENDS AND LABELS
AWGStandard Number of StrandsBending Radius
(Inches)
Insulation Thickness
(Mils)
Nominal Overall Diameter
(Inches)
Approx. Shipping Weight (Lbs/1000')Nominal DC Resistance OHM/1000' @ 20°CAmpacity @ 75°C*
1471.171100.29382.62420
1271.251100.31481.65025
1071.341100.34631.03935
871.461100.37860.65450
671.611100.401210.41165
471.811100.451760.25985
272.051100.512600.163115
1192.331250.583290.129130
1/0192.491250.624040.102150
2/0192.681250.674960.081175
3/0192.881250.726080.064200
4/0193.111250.787550.051230
250373.421400.868970.043255
350373.851400.9612270.031285
* Ampacity is from NEC Article 310. Check with local codes authority for guidance with your application.