RoHS Compliant Made in USA

Scope:

This single-conductor cathodic protection cable can withstand corrosive gases and brackish water. It is a direct earth burial DC feeder cable designed to prevent rust on exposed metal structures, including storage tanks, pipelines, wells, offshore oil platforms, subsea equipment, and ocean vessels.

Applicable Standards and Tests:

  • ASTM B-1, B-3, B-8, AND B-33
  • ICEA S-95-658/NEMA WC70

Features:

  • 600V RATED
  • DIRECT BURIAL RATED
  • 75°C MAX CONTINUING OPERATING TEMPERATURE IN WET OR DRY LOCATIONS

Construction:

Conductors:

Single conductors are solid or stranded and annealed or hardened uncoated copper.

Insulation:

Conductors are insulated with a concentrically applied PVDF (often referred to as Kynar®).

Jacket:

Conductors are jacketed with a concentrically applied black HMWPE (high molecular weight polyethylene).

LLDPE (linear low density polyethylene) is standard and HDPE (high density polyethylene) is available upon request.

Identification and Packaging:

Print legends on the wire include the manufacturer, conductor size, voltage rating, UL symbol (if applicable) and type designation. Standard length spools are 500 or 2500 feet.

Print Wheel:

KRIS-TECH WIRE CO. #XX AWG PVDF/HMWPE CATHODIC PROTECTION CABLE

Value Add Service:

  • CUSTOM LENGTHS AND PUT-UPS
  • 12 AVAILABLE COLORS
  • WIRE PARALLELING AND CABLING
  • WIRE STRIPING
  • CUSTOM PRINT LEGENDS AND LABELS
AWGStandard Number of StrandsBending Radius
(Inches)
Insulation Thickness (Mils)Jacket Thickness (Mils)Nominal Overall Diameter
(Inches)
Approx. Shipping Weight (Lbs/1000')Nominal DC Resistance OHM/1000' @ 20°C
1470.9720650.24322.624
1271.0520650.26411.650
101, 71.09 / 1.1420650.27 / 0.2955 / 561.039
871.2620650.32790.654
671.4120650.351140.411
471.6120650.401680.259
271.8520650.462520.163
1192.0120650.503100.129
1/0192.1720650.543830.102
2/0192.3620650.594750.081
3/0192.5620650.645850.064